Thermogravimetric analysis, of the obtained polymers, indicated good thermal stability up to 310 C. The polyurethane urea chemical structure was confirmed by FTIR analysis.
Get a quotePolyurethane composite embedded with microencapsulated phase change materials shows excellent thermal storage performance and good adaptability to …
Get a quoteForm-stable composite phase change materials exhibit considerable application prospects in the insulation of submarine oil and gas pipelines due to their good chemical stabilities, levels of thermal insulation, and leakage resistances. In this study, composite phase change materials (PU-MPCM) were prepared for application in …
Get a quoteFor instance, the storage modulus of TPU-Ta = 180 C samples at 200 C is around 18.6 MPa which is 3.5-fold higher than the storage modulus of the unannealed …
Get a quoteFourier-transform infrared (FTIR), scanning electron microscopy (SEM), and dynamic thermomechanical analysis (DMA) measurements reveal good compatibility between the polyurethane and wood flour...
Get a quotethe slope of the storage modulus increase: foams with higher blowing agent content ( Fig. 3 b and d) revealed a slower transition from a low modulus gel to a cross-linked solid.
Get a quoteThe primary viscoelastic functions storage modulus (E''), loss modulus (E'''') and loss tangent (tan δ) were measured at a constant frequency of 1 Hz as a function of …
Get a quoteA two-pack polyurethane coating was analyzed using thermoanalytical techniques. The curing reaction, monitored using pressure differential calorimetry (PDSC), rheometry and dynamic mechanical...
Get a quote4.8: Storage and Loss Modulus. Page ID. Chris Schaller. College of Saint Benedict/Saint John''s University. We saw earlier that the inherent stiffness of a material can be assessed by its Young''s modulus. The Young''s modulus is the ratio of the stress-induced in a material under an applied strain. The strain is the amount of deformation in the ...
Get a quoteWe proved in our earlier works [40] [41][42] that the temperature dependence of the storage modulus E (T) at a given constant oscillating frequency of dynamic mechanical loading for thermoplastic ...
Get a quoteSolids 2021, 2 110 not change, which is indicative of neutral or weak interactions. In addition to Tg, the elastic storage modulus of the filled polymers is known to be higher than the corresponding unfilled polymers, especially in the rubbery region [15]. In addition to ...
Get a quoteDespite polyurethane intrinsic rheologic complexity, the moduli/loss factor curves superimpose well over several decades of reduced frequency at the glass transition temperature (T g), 0 C and 15 C, the last temperature being considered the midpoint of the
Get a quoteIn this paper, a stiffness–temperature model based on Weibull statistics was applied to quantitatively describe changes in the storage modulus of thermoplastic …
Get a quoteThe measurement provided information in regard to the change of storage modulus (Eʹ), loss modulus (E″) and tan delta (tan δ) as a function of temperature. The glass transition temperature of the flexible segments (T gSS ) was determined based on the maximum tan δ peak.
Get a quoteIntroduction to Polyurethane Chemistry. Felipe M. de Souza,1 Pawan K. Kahol,2 and Ram K. Gupta*,1. 1Department of Chemistry, Kansas Polymer Research Center, Pitsburg State University, Pitsburg, Kansas 66762, United States 2Department of Physics, Pitsburg State University, Pitsburg, Kansas 66762, United States *Email: rgupta@pitstate .
Get a quoteThe storage modulus decreased signi - cantly when the temperature ranged from À20 C to 100 C. The penetration degree of POE at the interface of TPU and TPS increased with increasing temperature.
Get a quoteA summary of the experimental uniaxial tensile properties and the storage modulus at 75 C from dynamic mechanical analysis (DMA) is provided in Table 1 for a range of TPUs with varying HSC. The system analyzed is based on phenylene diisocyanate (PPDI) and butadienediol (BDO) for the hard segment and polycaprolactonediol (PCL) for …
Get a quoteThe TG analysis indicated that the decomposition of BPU and NPU can be divided into three similar stages with temperature ranges of <200 • C, 220-450/500 • C and above 500 • C. Activation ...
Get a quoteThe objective of this research is to prepare rigid polyurethane (PU) foams from α-phellandrene, a biobased compound. Two types of polyols were synthesized by reacting …